Welcome to ECOL - Join Free - Sign In
high pressure differential fan blower
high pressure differential fan blower
Supplier Info
[China Supplier]
Contact Person : Mr. Tang Guojun
Tel : 86-755-29882904
Fax : 86-755-33817926
Product Detail
1.Fan blower 2.Wide voltage and two frequency 3.Protection class IP55,insulation class F 4.Die cast aluminum ADC12 5.CE

Ribake high pressure differential fan blower

Advantages

 

Wide voltage and double frequencyIn protection class IP55, insulation class FPerfect surfaceEasy installation100% oil freeLow noise levelNo vibration and complete dynamic stabilityPulsation-free dischargeHigher pressure ratioCooler running NSK bearingsTemperature resist to 180°cWork 20,000 hours without maintenance 12 month warrantySuitable for environmental protectionAvailable in stock

Technology data(4BHB310-H26)

 

Order No.Frequency(Hz)Output(KW)voltage(V)current(A)Maximum airflow(m3/h)Maximum vacuum(mbar)Maximum pressure(mbar)Weight(Kg)Sound(db/A)

4BHB310-H26

50

0.81

200-240Δ/345-415Y

4Δ/2.3Y

66

-280

350

17

57

 4BHB310-H26

 60

 0.94

220-275Δ/380-480Y

 4Δ/2.3Y

 80

 -340

360 

 17

 62

 Dimensions 

 

Operating principle

 

     The impellers in the BHB-series machines are mounted directly on the motor shaft for noncontact compression entirely without friction. Maximum operational reliabilityk,even at high differential pressures,is ensured by the arrangement of the bearings outside the compression chamber.

 

     The gas is taken in through the inlet 1,As it enters the side channel 2,the rotating impeller 3 imparts velocity to the gas in the direction of rotation.Centrifugal force in the impeller blades accelerates the gas outward and the pressure increase.Everyrotation adds kinetic energy,resulting in the further increase.Everyrotation adds kinetic energy,resulting in the further increase of the pressure along the side channel.The side channel narrow at the rotor,sweeping the gas off the impeller blades and discharging it through the outlet silencer 4 where it exits where it exits the side channel blower.

 

Product features

 

   1.Designed and improved by the latest Europe technology,molded with high strengh ADC12 aluminum alloy,processed on precision CNC machine

 

   2.Two-pole motor with protection calss IP and insulation F,high temperature resistant to 180°c

 

   3.Motor reached Europe EFF2 standard,save more electricity,and more durable

 

   4.In front bearing structure makes dynamic stability

 

   5.The rotating parts are not in contact with the casing,no friction during operation,no internal lubrication needed

 

   6.All products ard strictly tested befored leaving the factory,such as no-load test,impulse winding test,frequency withstand voltage test etc.for motor.Pressure,airflow,noise test for blower

Applications 

Blow,hoover,exhaust,cool,transport,air cushion