door control:-Open Door Mode:Card or public code (1234)-Door open time:3 seconds-Anti-break Alarm:able-Alarm delay: 0 s
1.PRODUCT SPECIFICATION
Item specification
power DC12V+10%; 1.2A
Lock Relay 12VDC/2A
Temperature working: 0°C~45°C
storage: -10°C~55°C
Relative Humidity working: 40%~90%RH
storage:20%~90%RH
User Capacity 1000
Frequency 125KHz or 13.56Mhz
Card Type EM or Mifare compatible card
Read range EM: 5-15cm;
Mifare: 3-5cm
External Reader One extra W26 reader
Other Connections Lock, exit button, bell, door sensor, alarm
2.FACTORY DEFAULTED SET
Item Defaulted Value
Programming Code 881122
Open Door Mode Card or public code (1234)
Door open time 3 seconds
Anti-break Alarm able
3.THE LED AND BUZZER
3.1Normal working status
3.1.1. Valid command: short beep
3.1.2. In valid command: long beep
3.2Programming state
3.2...1Green LED on
3.2.2 Valid command: two short beeps
3.2.3 In valid command: Three beeps
4. Cancel Command
Press key # to cancel command before finish it
TA door controller