Industrial gas detector fixed gas detector Intrinsically safety circuit design ISO9001:2000 certificate

fixed industrial gas detector KB-501X with led display

KB-501X Online Gas detector uses high performance gas sensor and microcontroller and employs SMD technology.

KB-501X can translate the detected gas concentration signals into digital signals for display. Three-wire system 4~20mA electric current signals output, with long-distance transmission and good anti-interference capacity.

Features1. Advanced sensor; Cast Aluminium housing2. Intrinsically safety circuit design;3. High brightness LED digital display, clear and direct;4. Three-wire system 4~20mA standard signals output;5. Possible to connect to DCS system directly;6. Two-stage (low/high) alarm double switching value output;7. The probe has following advantages: high sensitivity, quick-response capacity, long performance life and short polarization time.8. Function of infrared remote control operation (remote-control is optional units).

Technical Specifications for KB-501X Combustible / Toxic / O2 Gas Detector 

Gas 1.Combustible/Flammable/Explosive gas
Detecting Range0~100% LEL
Alarm Threshold (two-stage) Low: 25% LEL / High: 50% LEL
Gas 2.Toxic/Harmful/Poisonous/Hazardous gas
Detecting RangeRefer to the gas parameter list
Alarm ThresholdRefer to the gas parameter list
Gas 3.Oxygen (O2)
Detecting Range0~30.0% vol
Alarm Threshold(Two-stage) Low: 18.5% vol High: 23.5% vol
Sensor TypeCatalytic Combustion sensor(Combustible gas); Electrochemical sensor(Toxic and Oxygen)
DisplayHigh brightness LED display
Working EnvironmentTemperature: -20~55°CHumidity: ≤95%RH (non-condensing)
Working Current≤170mA(Combustible gas); ≤50mA(Toxic and Oxygen)
Working Voltage16~30 VDC
Output Signals Three-wire system 4~20mA standard signals output
Power Consumption<3W(Combustible gas); <1 W(Toxic and Oxygen)
Alarm OutputTwo-way electrical relay tip output (30V 2A)
Installation MeansWall mounted
Transmission Distance≤1000m
Explosion-proof TypeExplosion insulating
Explosion-proof IndexEx d IIC T6
Protection GradeIP65
Product Dimensions140x179x86mm
Product Weight1.39Kg
Remarks: The detecting range and alarm threshold value can be adjusted according to customer’s request.

Toxic Gas Detected:NH3 (Ammonia) 0-100 ppm Cl2 (Chlorine) 0-50.0 ppmH2 (Hydrogen) 0-1000 ppmCH2O (Formaldehyde) 0-100 ppmH2S (Hydrogen Sulfide) 0-100 ppmHCl (Chlorine Hydride) 0-30.0 ppmHCN (Hydrocyanic Acid) 0-50.0 ppmPH3 (Phosphine) 0-20.0 ppmHF (Fluorine Hydride) 0-10.0 ppmNO (Nitrogen Oxide) 0-250 ppmCO (Carbon Monoxide) 0-500 ppmSO2 (Sulfur Dioxide) 0-20.0 ppm or 0-2000 ppmClO2 (Chlorine Dioxide) 0-50.0 ppmNO2 (Nitrogen Dioxide) 0-20.0 ppmC2H4O (Ethylene Oxide) 0-100 ppmO3 (Ozone) 0-20.0 ppm

Flammable Gas Detected:CH4 (Methane)C3H8 (Propane)H2 (Hydrogen)NH3 (Ammonia)C2H4O (Ethylene Oxide)CH3CH3 (Ethane)C2H4 (Ethylene)C4H10 (Butane)C4H8 (Butylene)C7H8 (Methylbenzene)C2H7N (Ethylamine)C8H10 (Ethylbenzene)CH4O (Methanol)C2H6O (Ethanol)C3H4O (Acrolein)C2H3Cl (Chloroethylene)C2H7N(Ethylamine)C3H9N (Isopropylamine)CH3Br (Methyl Bromide)Remarks: Some gas types are not listed yet. If request, please inform us.

fixed industrial gas detector KB-501X with led display

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.