HEIMAN GAS ALARM PRODUCTS
Carbon Monoxide and Gas Alarm HM-712DVS-AB
Features:
High Reliable Semiconductor CO Sensor and Gas Sensor
10 years Sensor Life
MCU Processing
Auto Charge Backup Battery Auto-Check Sensor Failure
Auto Reset After Gas / CO Clears
12V Pulse Output to Drive Solenoid Valve / Electrovalve to shut off gas supplySound & Flash Alarm
Different CO and Gas Alarm Audios
Technical Specifications:
Operating Voltage | 100-240V AC + 9V rechargeable battery backup | |
Temperature Range | 0°c ~ +50 °c | |
Humidity Range | 10% to 95% relative humidity (RH) | |
Alarm Level | CO 150PPM ±80PPM Natural Gas: 10%±5%LEL(5000PPM±2500PPM) | |
Alarm Reset | Automatic Reset after CO or Gas Clears | |
Sensor | CO Sensor: Semiconductor; Gas Sensor: Semiconductor | |
Indicator Lights | AC Power: Constant Green Light ON Alarm: RED Light Rapidly Flashing Sensor Fault: Constant Yellow Light | |
Audio Alarm | 85dB at 10 feet Gas Alarm: Continuous Beeps Carbon Monoxide Alarm: 3 beeps, pause, 3beeps | |
Dimension | 118.5 x 82 x 43mm |
Carbon Monoxide and Gas Alarm with Backup Battery and Valve Output