30kw screw air compressor
Fully automatic load and unload. Compressor will start automatically and shut down under the following conditions:
- When the target pressure in the air tank has been reached
- When the voltage drops below a thrashold
- In an over-pressure condition
- When the temperature reaches a protection setpoint
High-quality European technology and components (GHH-Rand and SKF)
M-H air filter with long-life capability.(4000 hours+), easy for maintenance and replacement.
M-H oil filter, filtration density 10 micron (99.9% efficiency) and long-life capability (4000 hours+).
M-H air-oil separator, particle count below 3 ppm
Control system: All parts are by Schneider in France
Specification of screw air compressor:
Model | Capacity/pressure M3/min/Mpa | Compre ssing stage | Tem of delivery | Power (V/ph/Hz) | Motor (kw) | Start method | Dia. of hole | Drive |
KVB-25A | 3.22/0.7 | One Stage | Air cooling: <surroun dings +15°C | 380/3/50 | 18.5 |
| G1.25” | Belt drive |
3.01/0.8 | G1.25” | |||||||
2.52/1.0 | G1.25” | |||||||
2.3/1.2 | G1.25” | |||||||
KVB-30A | 3.6/0.7 | 22 | G1.25” | |||||
3.56/0.8 | G1.25” | |||||||
3.07/1.0 | G1.25” | |||||||
2.84/1.2 | G1.25” | |||||||
KVB-60A | 7.36/0.7 | 45 | G1.5” | |||||
7.1/0.8 | G1.5” | |||||||
6.47/1.0 | G1.5” | |||||||
5.8/1.2 | G1.5” | |||||||
KVB-75A | 10.83/0.7 | 55 | G2” | |||||
9.2/0.8 | G2” | |||||||
8.61/1.0 | G2” | |||||||
7.71/1.2 | G2” | |||||||
KVB-100A | 14.11/0.7 | 75 | G2” | |||||
13.02/0.8 | G2” | |||||||
12.04/1.0 | G2” | |||||||
10.06/1.2 | G2” |