Welcome to ECOL - Join Free - Sign In
120W switching power supply (S-120-3)
120W switching power supply (S-120-3)
Supplier Info
[China Supplier]
Contact Person : Ms. Xu XiuQin
Tel : 86-0577-61755289
Fax : 86-0577-61755389
Product Detail
1.120W Series switch power supply 2.CE/ISO9001 certificate 3.100% burn-in test,shortest lead time 4.Samples available 120W switch power supply Competitived price and high reliability 105oC Output capacitor AC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effeciticly With short-circuit and overload protection Compact size, light weight 100% full-load burn-in test Installed with EMI filter, minimum wave

ModelS-120-3S-120-5S-120-7.5S-120-12S-120-15S-120-24S-120-27S-120-48
DC output voltage3V5V7.5V125V15V24V27V48V
Output voltage range(Note:2)±2%±2%±1%±1%±1%±1%±1%±1%
Rated output current22A24A16A10A8A5A4.4A2.5A
Output current range0-22A0-24A0-16A0-10A0-8A0-5A0-4.4A0-2A
Wave and noise(Note:3)100mV100mV100mV100mV100mV100mV100mV100mV
Inlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
Load stability(Note:5)±0.5%±1%±0.5%±0.3%±0.3%±0.2%±0.3%±0.2%
DC output power66W120W120W120W120W120W119W120W
Efficiency70%78%80%81%81%84%84%84%
Adjustable range for DC voltage2.85~3V4.75~5.5V6.75~8.25V10.8~13.2V13.5~16.5V21.6~26.4V26~32V43.2~52.8V
AC input voltage range85~132VAC/180~264VAC selected by switch, 47~63Hz; 255~370VDC
Input current2.4A/115V 1.2A/230V
AC inrush currentCold-start current 30A/115V 60A/230V
Leakage current<1mA/240VAC
Overload protection105%~150%150%~200%105%~150%
Type: Output shutdown Reset: Recycle AC ON/OFF
Temperature coefficient±0.03%/°c(0~50°c)
Setup, rise , hold up time200ms,100ms, 30ms
Vibration10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvAC
Isolation resistanceInput and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ
Working temperature and humidity -10°c~+60°c(Refer to output derating curve), 20%~90%RH
Overall dimension199×98×38mm
Weight0.66Kgs
Safety standardsMeet UL 1012 requirementNot apply forr the mark
EMC standardsMeet FCC PART 15 J Conduction class B

Note:                                                                                                                                                                      1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer.                   

2. Error: include the setting error, line stability and load stability.(Note:5)                                                                    

3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.                

4. Inlet woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.                          

5. Load stability test: The load is from 0% to 100%

120W switching power supply (S-120-3)