solar water heater: 1.SRCC,Keymark,CSA,UL,SABS,CE,ISO approved 2.High pressurized 3.OEM retail available

Split Pressurized Solar Water Heater

 Haokang split pressurized solar water heater is specially designed for the villa. The split means that the collector separates from water storage tank. Collector may be installed either on the roof or wall while water tank may be installed at any place in a villa flexible. Collector harmonizes with villa’s outlook beauty.  

Product features:  

1. Perfectly concordant with the architecture appearance.

2. Solar collector can be installed on roof, balcony or wall of flat, sloping or vertical sides.

And the storage tank can be installed in room instead of being exposed outdoors.

3. Anti-freezing, more suitable in cold areas, Fast start up on cloudy or rainy weather.

4. Water does not flow in vacuum tubes, that preventing the collectors from freezing and bursting in cold climate. Realize hot water available for all year around  in cold areas.

5. No water inside vacuum tubes, breakage of some tubes will not inflence the ordinary operation of the whole system.

6. Equipped with electric heater, working station, completely automatic cooperation.

7. Whenever you need hot water regardless of time and weather.

8. Equipped with magnesium bar what improves the water quality and lengthens the lifespan of the storage tank.

9. It can produce hot water with constant temperature.

10.Indirect solar system enable water quality to be much cleaner than direct solar system.

8. Time of uploading water is cut, 24 hours water supply on condition that pipeline is working.

9. Life duration: 15 years, warranty: 5 years

10. Lead time: 5-7 days for a 20ft container, 10-15 days for a 40ft container

11. OEM,ODM offered.

12. To serve Europe, America, Africa clients better, at work in Europe work time.

Working principle:

1. When the temperature of the heat collector. reaches the set value, the controller shall start the circulation pump automatically;

2. The circulation pump makes heat---conducting liquid circulate automatically;

3. The heat---conducting liquid transfer heat to water by the heat exchanger in the water tank;

4. In case the temperature of the circulation pump does not reach the set value, the circulation pump shall be stop working automatically;

5. In case the temperature of the water tank does not reach T-max, then start the electrical heater.

 

Components:

1. Heat pipe solar collector(solar thermal collector)

      The heat pipe solar collector are connected with existing water heating device. The selective coating on the inner cover of vacuum tube absorbs solar energy and transfer heat to heat pipe by aluminium fins, the medium in heat pipe changes into air and rise to condenser. Then heat pass through heat exchanger and meanwhile, vapour becomes liquid and go back to bottom of heat pipe. Continuous water heating in pipeline is based on the circulation of this heat transfer process.

 1. The perfect combination of vacuum tube and heat pipe makes higher heat efficiency: heat pipes quick transfering capability, vacuum tubes selective absorb coating and heat preservation integrate that makes them superior heat performance.

 2. Wide applicable range: as the heat pipe has less heating space for medium, it can function quickly even on cloudy day. It can work normally even in -40degree centigrade. As no water flows in vacuum tube, it can avoid frost cracking or scaling which influence heat efficiency.

3. Each individual tube can work independently, and the whole system can keep working if individual tube is broken. The lifespan of heat pipe vacuum tube is over 15 years.

4.The unique connection design of heat pipe and vacuum tube can ensure seal tightness and tube replacement convenience

 

2. Pressurized water tank(80-1000L, 6 bar pressure, P/T safety valve, heating element, magnesium bar, heat exchange copper coils)

 

3. Working station(expansion vessel, circulation pump, controller, piezometer )

     Expansion vessel

 

 Closed-loop systems require a expansion vessel, an expansion vessel has a vessel in which air is locked inside a bladder or diaphragm. It screws into standard 1/2 inch or 3/4 inch threaded plumbing fittings. When pipes are filled with heat transfer fluid (water and glycol ),and the operating pressure of the system is set, the fluid will occupy a given volume on the temperature. As the fluid is heated by sunshine, it expands. This is why the expansion vessel is necessary. The expansion vessel allows the fluid to safely expand by compressing the air in the chamber.

 

Working temperature: -10 to 99 degree centigrade

 

Max working pressure: 10 bar

 

 

     Circulation pump

 

Brand: Wilo

 

Suitable fluids: water/glycol mixture, max mixing ratio 1:1, mixing ratio required for hydraulic collector above 20%.

 

Manual 3 speed control

 

Fluid temperature range -10 to +110 degree centigrade

 

Max working pressure: 10 bar

 

 

    Intelligent controller

4. Relevant copper parts for connection.

Specification:

Inner tank:stainless steel SUS 304-1.2~2.5mm/porcelain inner tank
Out tank:painted steel-0.6mm/stainless steel-0.6mm
Insulation: 47.5-60mm polyurethane
The use pressure:<6 bar
The test pressure:10 bar
tank installation method: vertical
manifold channeladopts copper steel, each one can endure 1.0Pa
vacuum tube: 3 target AL/SS/CU with heat pipe, can reach 350 when exposure in the sunning
bracket:galvanized sheet with electrostatic plastic coating, thickness: 1.5mm
Accessories:Electric heater,The temperature and pressure relief valve The sensor The copper coil heat exchanger: one or two The drain pipe
working stationtop quality(Germany WILO circulation Pump +Switzerland   flowmeter + Italy expansion vessel +safety valve +manometer)advanced designed pumping station

Popular Model No:

Set No.Diameter of inner/outer water tank(mm)Heat pipe vacuum tubeTank capacity   (liters)
qty (pcs)size (mm)
HK-SPS-Z200-H20450/55020Φ58 X 1800200
HK-SPS-Z240-H24480/58024Φ58 X 1800240
HK-SPS-Z300-H30480/58030Φ58 X 1800300
* HK-SPS-S200-H20450/550,1 copper coil20Φ58 X 1800200
HK-SPS-S250-H24480/580,1 copper coil24Φ58 X 1800240
* HK-SPS-S300-H30480/580,1 copper coil30Φ58 X 1800300
* HK-SPS-D200-H20450/550,2 copper coil20Φ58 X 1800200
HK-SPS-D250-H24480/580, 2 copper coils24Φ58 X 1800240
* HK-SPS-D300-H30480/580, 2 copper coils30Φ58 X 1800300

Detail Photo Showing:

Business Terms:

Delivery time:10days for samples load
20days for container load
Payment Term:30% days payment by T/T,The balance 70% by T/T against the Copy of B/L
Gurantee:5 years, the accessories 1 years
M&Q20FT Container
 LCL,there will be some extra cost depend on Items and quantity
Price Term:FOB prefered,CFR and CIF acceptable

Seperated pressurized solar water heater which approved by CSA,Solar keymark,SRCC,En12975

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.