Instructions
1) Input Signal
The pump is on unload condition when the pump is operated without input signal voltage.
2) Electric Source
Always turn off electric source whenever the connector for swash plate tilt angle sensor is removed.
3)Compensation of Pump Maximum Regulated Flow at Frequency
If the same maximum flow is required at Hz or 60 Hz,connect short plug in the amplifier to 60 Hz at the place where supplied frequency is 60Hz .At this condition,maximum flow comes to the same value at 50Hz.
If short plug is used at 60Hz without making the change, maximum flow increased in proportion to frequency.
4)Paiting on Amp.Box and Solenoid
To maintain suitable radiation effect,the amp.box and the solenoid of the control valve should not be painted.