Product Detail
1)Use for electric wiring 2)pvc copper wire 3)in Electrical Equipment and Supplies 4)single core cable

Standard

The cable is manufactured according to GB5023-2008 and JB8734-1998 national standard

or international standard of 60227IEC.

Application

The cables can be applied to the copper(aluminum)-core cables in the rated A/C voltage of

U/U450/750V and the below power, lighting, daily electric appliances, apparatus and

telecommunication equipments.

Operation characteristics

1-U0/U is 450/750V and 300/500V ;

2-The allowed long-term working temperature of wire should not exceed 70°C;

The cable (wire) shall be installed at temperature not lower than 0°C;

3-The bending radius shall not be less than 4D of the cable overall diameter it is less

25mm; the bending radius shall not be less than 6D of cable overall diameter when it

is more than25mm.

Manufacture length

1-The coil length of cable (wire) shall be 100M, filled reel length shall be more than 1000M;

2-The short cable are permitted with a length not less than 10m for each and their quantity

shall not exceed 10% of the total supply length, and short length quantity of every piece

not more than 2pcs;

3-Any supply length is permitted based on the agreement with buyer. The error of metering

shall not exceed ±0.5%.

TypeDescriptionSpecification
Rated voltage (V)No. of coresNominal cross-sectional area (mm2)
BVCu conductor PVC insulated cable(wire)300/50010.75-1
227 IEC 01(BV)Single-core hard conductor non-sheathed cable(wire)450/75011.5-400
        
BV 300/500V Cu conductor PVC insulated cable (wire)
        
Nominal cross-sectional area (mm2)Construction of conductor (No. of wires)Insulation thickness (mm)Max Outer diameter (mm)Max. D.C. resistance at 20°C (Ω/km) Min Insulation resistance at 70°C (MΩ/km)Current rating in air at 25°C (A)Approx. Weight of cable (kg/km)
0.75 10.62.424.50.0121310.9
1.00 10.62.718.10.0132011.5
        
227 IEC 01(BV)450/750V Single-core hard conductor non-sheathed cable(wire)
        
Nominal cross-sectional area (mm2)Construction of conductor (No. of wires)Insulation thickness (mm)Max Outer diameter (mm)Max. D.C. resistance at 20°C(Ω/km) Min Insulation resistance at 70°C (MΩ/km)Current rating in air at 25°C (A)Approx. Weight of cable (kg/km)
1.5 10.7 3.312.10.0112519.9
2.5 10.8 3.97.410.013431.4
4 10.8 4.44.610.008544.546.3
6 10.8 4.93.080.0075866
10 71.0 6.41.830.00779.5116
16 71.0 81.150.005111175
25 71.2 9.80.7270.005146275
35 71.2 110.5240.004180372
50 191.4 130.3870.0045225496
70 191.4 150.2680.0035280701
95 191.6 170.1930.0035344969
120 371.6 190.1530.0032397.51202
150 371.8 210.1240.00324551478
185 372.0 23.50.09910.00325191853
240 612.2 26.50.07540.00325412417
300 612.4 29.50.06010.0036363024
400 612.6 33.50.0470.00287273825

Certification:

    

     

Packing Picture:

1.5MM2 BV single core electrical cable use in building

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.