Welcome to ECOL - Join Free - Sign In
Foxboro DCS Module-FBM202-P0926EQ
Foxboro DCS Module-FBM202-P0926EQ
Supplier Info
[China Supplier]
Contact Person : Ms. Sun Cindy
Tel : 0086-592-3108656
Fax : 0086-0592-3265129
Product Detail
Foxboro DCS Modules 1.Itme no.:FBM202 P0926EQ 2.General Agent of Foxoboro in China 3.Competitve price and good service

Foxboro DCS Modules: FBM List

Module #

Function

Application Program

Software Function

PSS #

FBM201

Channel Isolated, 8 Input 0-20 mA

Analog input

Conversion time, rate of change limits

PSS 21H-2Z1 B4

FBM202

Channel Isolated, 8 Input Thermocouple/mV

Analog input

Conversion time, rate of change limits

PSS 21H-2Z2 B4

FBM203

Channel Isolated, 8 Input RTD(Platinum, Nickel, Copper)

Analog input

Conversion time, rate of change limits

PSS 21H-2Z3 B4

FBM204

Channel Isolated, 4 Channel 0-20mA In + 4 Channel 0-20mA Out

Analog I/O

Conversion Time, Fail-Safe Configuration(Hold/ Fallback on per channel basis)

PSS 21H-2Z4 B4

FBM205

Channel Isolated, 4 Channel Redundant 0-20mA In + 4 Channel Redundant 0-20mA Out

Analog I/O

Conversion Time, Fail-Safe Configuration(Hold/ Fallback on per channel basis)

PSS 21H 2Z5 B4

FBM207

Channel Isolated, 16 DIN Voltage Monitor

Discrete I/O

Input filter time

PSS 21H-2Z7 B4

FBM207b

Channel Isolated, 16 DIN 24VDC Contact Sense

Discrete I/O, or ladder logic

Input filter time

PSS 21H-2Z7 B4

FBM207c

Channel Isolated, 16 DIN 48 VDC Contact Sense

Discrete I/O, or ladder logic

Input filter time

PSS 21H-2Z7 B4

FBM213

Group Isolated, 8 Input RTD

Analog input

Conversion time, rate of change limits

PSS 21H-2Z13 B4

FBM214

8 Input Hart Communication, 4-20mA input signal

Analog input

Support for the HART commands necessary to interface the field device with the I/A series system database

PSS 21H-2Z12 B4

FBM216

Redundant Ready HART Inputs, 8 Channels

FBM217

Group Isolated, 32 Discrete Input

Discrete I/O, or ladder logic

Input Filter Time

PSS 21H-2Z17 B4

FBM219

Discrete I/O, 32 Channels, 24 DIN voltage monitor+8 DOUT pulse, group isolated

Discrete I/O, or ladder logic

Input filter time, Fail-Safe Configuration, Fail-Safe fallback, Sustained and Momentary output. If momentary output configurable is needed, pulse output interval can be also configurable.

PSS 21H-2Z19 B4

FBM211

Differential Isolated, 16 differential Input 0-20 mA

Analog input

Conversion time, rate of change limits

PSS 21H-2Z11 B4

FBM224

4 Modbus Communication Channels

Provides a interface between MODBUS salve devices and the Controller Process of I/A series system

PSS 21H-2Z24 B4

FBM231

Four Serial Ports, Redundant

Provides a serial interface between dual-ported field I/O devices and I/A series system

PSS 21H-2Z31 B4

FBM233

10/100 Mbps Ethernet, Redundant

PSS 21H-2Z33 B4

FBM237

Channel isolated, 8 channel 0-20mA output, redundant

Analog I/O

Output Fail-Safe Configuration(Hold/ Fallback on per channel basis)

PSS 21H-2Z37 B4

FBM241

Channel Isolated, 8 channel voltage monitor, 8 channel DOUT pulse, external power

Discrete I/O, or ladder logic

Input filter time, Fail-Safe Configuration, Fail-Safe fallback, Sustained and Momentary output. If momentary output configurable is needed, pulse output interval can be also configurable.

PSS 21H-2Z41 B4

FBM242

Channel Isolated,16 External Source DO

Discrete I/O, or ladder logic

Fail-Safe Configuration

PSS 21H-2Z42 B4

24 Port

Fiber E'net Switch w/24 MT-RJ Ports & Uplink Ports

Rapid scaling Tee Protocol(RSTR), manages redundant paths, prevent loops, and provides high speed convergence time for a network

PSS 21H-7C3 B4

Foxboro DCS Module-FBM202-P0926EQ

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.