They are capable of working under heat caused by ratedcurrent and expected short impacting current up to 100KA ApplicationsThese fuse holders are supporters for fuses with size up to 22x58mm. They are capable of working under heat caused by ratedcurrent and expected short impacting current up to 100KA. It canalso function as a fuse disconnecting switch by multi-phasecombination. There are two in/out lines at the RT18N fuse base,providing a power cut function. The RT18L type has a safety lockto lock the fuse carrier when disconnected to avoid wrong operation;it can also be equipped with an indicator, which goes on when thefuse linke breaks. Rated insulate voltage up to 690V; Working frequency 50Hz AC;Conventional free air thermal current up to 125A; Compliant withGB13539.1, GB13539.2, GB13539.6, GB14048.3 and IEC269-1,IEC269-2, IEC269-2-1, IEC947-3 . Design FeaturesAfter the plastic-injected case is equipped with contacts andfuse links, the bases are formed by welding or riveting bothcapable of being multi-phase structured. FB15C, FB16-3J, FB19C-3J, RT19 are open-structure, and others are semi-concealedstructure. There are five fuse sizes available to choose from for thesame fuse base of RT18N, RT18B and RT18C. There are two setsof in-out lines for RT18N. One is installed with fuse links of theaccording size. The other is a permanent open contacts withdouble breaking points. The whole base unit can cut the power.RT18 bases are all DIN rail installed, among which the RT18L isequipped with safety lock against wrong operation in the breakingstate. Base DataThe models, rated insulate voltage, rated current, and dimensions are shown in Figures 1~14 and Table 1~14 (Width of N-phasecombination is Bn-nB). Table 1
ModelsFuse Link models Rated insulation voltage (V) Conventional free air themal current (A) Dimensions/ Sizes(mm) Weight (g)
Fig.
RT14-2010x3850020Bolt installing hole Φ4.5 Figure 138
RT14G-2010x3850020Widt 15mm rail installation Figure 144
 Table 2
ModelsFuse Link models Rated insulation voltage (V) Conventional free air themal current (A) Dimensions/ Sizes(mm) Weight (g)
Fig.A1BH1H2Φd
RT14-3214x5150032Figure 2 10526.5571355.5148
RT14-6322x5850063Figure 2 12535661585.5241
 Table 3
ModelsFuse Link models Rated insulation voltage (V) Conventional free air themal current (A) Dimensions/ Sizes(mm) Weight (g)
Fig.A1A2BH1H2
RT18-32(X)10x3850032Figure 5 798118618059
RT18B-108.5x2350010Figure 5 808218607859
RT18B-1610x25.850016Figure 5 808218607859
RT18B-208.5x31.550020Figure 5 808218607859
RT18B-2510x31.550025Figure 5 808218607859
RT18B-3210x3850032Figure 5 808218607859
RT18C-108.5x2350010Figure 5 777818628156
RT18C-1610x25.850016Figure 5 777818628156
RT18C-208.5x31.550020Figure 5 777818628156
RT18C-2510x31.550025Figure 5 777818628156
RT18C-3210x3850032Figure 5 777818628156
RT18M-3210x3850032Figure 5 787818608056
HG30-3210x3850032Figure 5 788018738857
RT18-63(X)14x5150063Figure 5 1031052780110192
 Table 4
ModelsFuse Link models Rated insulation voltage (V) Conventional free air themal current (A) Dimensions/ Sizes(mm) Weight (g)
Fig.
RT18N-108.5x2350010Figure 6 70
RT18N-1610x25.850016Figure 6 62
RT18N-208.5x31.550020Figure 6 63
RT18N-2510x31.550025Figure 6 62
RT18N-3210x3850032Figure 6 62
 