Fusion splicer JX9010
Main Technical Parameter | |
Applicable Fiber | SMF(ITU-T G.652),MMF(ITU-T G.651),DSF(ITU-T G.653),NZDSF |
Average Splicing Loss | 0.02dB(SM),0.01dB(MM),0.04dB(DS),0.04dB(NZDS) |
Return Loss | <-60dB |
Operation Mode | Auto,Half auto,Manual |
Align Mode | Advanced PAS align mode. |
Fiber Diameter | clad diameter 80µm~150µm,coating diameter 100µm~1000µm |
Cleave Length | 8~16mm(coating diameter<250µm), 16mm(coating diameter 250~1000µm) |
Magnification | Vertical 152times,horizonl 304times. |
Image Display | 5.7’ 640*480 LCD. |
Pull Test | Standard 2N(optional). |
Heat-Shrinkable Tube | 40mm,60mm and a series of micro Heat-Shrinkable Tubing. |
Battery Capacity | Typcally splice 220 times, charging for 3.5 hour(available when charge). |
Battery Lifetime | Cycle life up to 300~500 times,replaceable. |
Electrode Lifetime | >4000 times,replaceable |
Lighting for Construction | Built-in super High-brightness LED supply convenience for night work |
Ports | USB,VGA |
Power Supply | Built in 11.1V Lithium Ion Battery.AC adopter(input AC100~240,output DC13.5V/4.5A) |
Environment Adaptation | Temperature range -10°C~50°C Humidity 95%RH(40°C,no condensing) Altitude 0~5000m |
Size | L×W×H=160×150×140(mm) |
Weight | 2.3kg(no battery ), 2.8kg(include battery) |
Optical power meter--TAM8701
Model | Handheld Power Meter A | Handheld Power MeterC |
Wavelength Range(nm)*1 | 800~1600 | |
Detector Type | InGaAs | |
Measurement Range(dBm)*2 | -70~+3 | -50~+26 |
Uncertainty *3 | 0.15dB | |
Accuracy | Linear 0.1% or Nonlinear 0.01dBm | |
Operating Temperature() | -10~+60 | |
Storage Temperature() | -25~+70 | |
Auto-off Time(min) | 10 | |
Operating Time(h) | >=130 | |
Battery | 3 AA1.5V | |
Weight(g) | 200 | |
Dimensions(mm) | 152*74*26 |
Optical light source--TAM8702
Technical Specifications
Type | TAM8702 | ||||
Wavelengths(nm) | 650 | 1310/1550 | 850/1300 | 850/1300/1550 | 850/1300/1310/1550 |
Emitter Type | FP-LD,LED or others please specify | ||||
Typical Output Power (dBm) | 0 | -7dBm for LD, -20dBm for LED | |||
Spectral Width(nm) | <=10 | ||||
Output Stability | 0.05dB/15mins; 0.1dB/ 8hours | ||||
Modulation Frequencies | CW,2Hz | CW,270Hz,1KHz,2KHz | |||
Optical Connector | FC universal adaptor | FC/PC | |||
Power Supply | Alkaline Battery(3 AA 1.5V batteries) | ||||
Battery Operating Time(hour) | 45 | ||||
Operating Temperature(¡æ) | -10~+60 | ||||
Storage Temperature(¡æ) | -25~+70 | ||||
Dimension(mm) | 152X74X26 | ||||
Weight | 180g | ||||
E-JIAXUN Recommendation | |||||
TAM8702 Handheld Light Source is designed for optimal use with JW3208 Optical Power Meter for measuring optical loss on both single mode and multimode fiber cable. |
fibra optica FTTH--Splicing+testing tools kit