Telemetry System with Defibrillator / Monitor
Telemetry System with Defibrillator / Monitor (CU-HD1)
Product overview:
Key features:
Product specification:
Display | |
LCD Dimension | 7 inch Diagonal (152mm * 91mm) |
Type | TFT Color |
Resolution | 800 * 480 pixels |
Defibrillation | |
Defib Common | |
Waveform | Truncated Exponential Biphasic (e~cube) |
Charge Time | Adapter : Less than 5 seconds to 200Joules Battery : Less than 7 seconds to 200Joules |
AED Mode | |
Output Energy | 200J |
Shock Delivery | Via multifunction defib electrode pads |
AED Develop Guideline | Shock advisory sensitivity and Specificity meet AAMI DF-80 guidelines |
Voice & Text Prompt | Guide the user through the protocol via multifunction defib electrode pads |
Manual Mode | |
Output Energy(Selected) | 1~10J, 15J, 20J, 30J, 40J, 50J, 100J, 120J, 150J, 170J, 200J |
Shock Delivery | External Paddle (with Pediatric) / Internal Paddle |
Synchronous Cardioversion | |
Printer | |
Continuous ECG Strip | Real-Time (8 seconds delay) |
Auto Printing | Recorder can be configured to print marked event, charge, shock And alarms |
Printing Speed | 25mm/s |
Paper | 50mm Width / 40mm Diameters |
Automatic Self-Test | |
Power on Self-TestRun Time Self-TestManual Self-TestPeriodic Self-Test(Daily/Weekly/Monthly) | |
Power Source | |
External Battery Pack : Lithium Polymer | |
Type | 14.8V 3.1Ah (Rechargeable) |
Capacity | When new, minimum of 100shock deliveries(200J) |
AC Power Pack | |
Output | 18V, 6A |
Noninvasive Pacing | |
Waveform | Monophasic Truncated Exponential |
Mode | Demand and Fixed Mode |
Amplitude Accuracy | 0 ~ 200mA (5mA) |
Pulse Width | 20ms(1.5%) |
Pulse Rate | 30 ~ 180ppm (1.5%) |
Refractory Period | 340 msec (30 to 80 ppm) 240 msec (90 to 180 ppm) |
SpO2 Pulse Oximetry | |
Saturation | 70 ~ 100%(3digits) |
Pulse Rate | 20 ~ 250bpm(3bpm) |
Perfusion | 0.2% |
Module Manufacturer | Nellcor |
SpO2 Alarm | Less than Minimum setting rate Over than Maximum setting rate |
Data Storage | |
External memory card | SD Card(ECG data, Evend, Voice) |
ECG Monitoring | |
Input | 3-Lead Cable : I, II, III 5-Lead Cable : I, II, III, aVR, aVL, aVF or V 10-Lead Cable : I, II, III, aVR, aVL, aVF or V1, V2, V3, V4, V5, V6 (Display View:All 12-Lead ECG waves display simultaneously) |
Lead Fault | “Lead Fault” messege and dashed line display, If an electrode or lead wire becomes disconnected |
Heart Rate Display | 30 to 300 bpm (3bpm) |
ECG Size | 5, 10, 20mm/mV and Auto-gain |
Heart Rate/Arrhythmia Alarm | HR, Asystole, VF, VT |
Accessories:
Standard Package | |
- Device- External Paddle (Reusable) - Pediatric included Power cord- 3-Lead ECG Cable- ECG Electrodes (15EA)- Disposable Defi Pads & Adapter for Defi pads- Built in Printer- Power Cord & SMPS (Switching Mode Power Supply)- Internal Battery (Lithium Polymer)- Gel- User Guide | |
Optional Accessories | |
- Carrying Case - SD Card / SD Card Reader - Pediatric Defi Pads (Disposable) - 5-Lead ECG Cable (Button Type) - ECG Electrodes (50EA) - Printer Paper (10 rolls) - Cigar Lighter Jack for Car - Bed Hanger - SpO2 Module Set (MP100, Finger Probe, Exention Cable) - Pacer - 10 Lead ECG Cable- Noinvasive Blood Pressure (NIBP) | |
Pictures:
Telemetry System with Defibrillator / Monitor (CU-HD1)