Welcome to ECOL - Join Free - Sign In
Truck Type Vacuum Circuit Breaker
Truck Type Vacuum Circuit Breaker
Supplier Info
[China Supplier]
Contact Person : Ms. Liu Yu
Tel : 86-917-6732965
Fax : 86-917-6732963
Product Detail
ZN39-40.5 truck type high voltage VCB meet relative GB and IEC standard high reliability, good credit

ZN39-40.5 type indoor HV vacuum breaker is used for many kinds of switchgear like JYN1-35 and GBC-35. It is widely used for 40.5kV voltage systems which is accordance with GB1984-2003 standards.

This series include: Vacuum circuit breaker truck, isolation truck and fuse truck;

 Structural Characteristcis:

1. The vacuum circuit breaker adopts air insulation; it can meet air distance and creepage under normal ruuning condition;

2.the operating mechanism use CT19N type mechanism, the outlet curve has good adaptation with requirements of vacuum interrrupter. It has high reliable with characteristics of long life, easy maintance and free-maintenance for operationg mechanism;

3.The truck can be pushed in or out easily; compulsive mechanical interlock way is adopted; Meet "Five Prevention" function; Suitable for varies site and the working sites which have rigorous running condition;

 Main Technical Specification

S.N

Name

Unit

Data

1

Rated voltage

kV

40.5

2

Rated frequency

Hz

50

3

Rated current

A

1250

1600

1250

1600

2000

4

Rated short circuit breaking current

kA

25

31.5

5

Rated peak withstand current

kA

63

80

6

Rated short-circuit duration

S

4

7

Rated power frequency withstand voltage

Between phases, phase to ground

kV

95/1min

Between gaps

8

Rated lightning impulse withstand voltage

Between phases, phase to ground

kV

185

Between gaps

9

Rated operating sequence

 

0-0.3s-CO-180s-CO

10

Power source voltage of opening and closing circuit

V

~220/110;-220/110

11

Rated breaking current of single capacitor bank

A

630

12

Rated breaking current of back to back capacitor bank

A

400

13

Electrical endurance class

 

ClassE1(20cycles)

14

Mechanical endurance

Cycle

(classM1)10000

15

Operating mechanism type

 

CT19N

CD10II

16

Clearance between open contacts

mm

22 ±2

17

Contact stroke of contacts

mm

6 ±1

18

Out of simultaneity of CO operations of three poles

ms

«2

19

Contact bouncing duration at closing operation

ms

«3

20

Closing time

ms

30~100

21

Opening time

ms

30~60

22

Average closing speed

m/s

0.6 ±0.2

23

Average opening speed

m/s

1.6 ±0.3

24

Main circuit resistance of each pole

 μΩ

«80

Truck Type Vacuum Circuit Breaker

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9