Aluminum ceiling tile
Ceiling tile
ceiling tile can be an art especially when the aluminum ceiling tile appeared.with outstanding advantage.aluminum ceiling tile is environmental protection .less pollution.fashion and populour .
especially with perforate aluminum ceiling tile,which gurantte the breath freely with the air-hole meaning time deadening. the plus is with one piece of film cushion inside will helping with absorption of moisture .what perfect for Kitchen &Bathroom..
Ceiling tile
Code | Items | Unit | Standard of requirements |
1 | Material of singal Aluminum plate | The material of singal aluminum plate shall meet GB/T3880-1997 | |
2 | Length of Singal Aluminum Plate | mm | 1 |
3 | Width of Singal Aluminum Plate | mm | 1 |
4 | Diagonal Warp of Singal Aluminum Plate | mm | 2000 |
5 | Rolding Height Diagonal Warp of Singal Aluminum Plate | mm | 0.4 |
6 | Angle of Singal Aluminum Plate | (.) | 2 |
7 | Plane of Singal Aluminum Plate | mm | 2000 |
8 | Appearance | Coating shall smooth with even color without obvious flowing tracks crease air bubble crack scratch and impurity or other surface defactions which influence usage | |
9 | Thickness of Dry Coating | um | Secondary Coating:average coating thickness:30 Minicon coating thickness:25 Third coating : average coating thickness:40 Minimum coating thickness:35 |
10 | Color Unlformity of Coating | Color uniformity shall meet the color code approved color different of both parties | |
11 | Hardness of Coating | 1H | |
12 | Adhesion of Dry Coating | Class | Better than class O |
13 | Adhesion of Wet Coating | After test dip it into 30C5c distilled watr or negative lon water for 24H the dry filmin the area shall be peel off or displace | |
14 | Boiled Water Adhesion of Coating | After test dip it into 95C distilled water or negative lon water for 20min the dry film in the area shall be peel off or displace. | |
15 | Anti-impact of Coating | After 392Ncm impactlost the dry film shall not crack or peel off | |
16 | HydrochloricAcld Resisitance of Coating | After testing in 10Hydrachloric acld solution for 15min the coating surface shall have no air bubbies and visible changes | |
17 | Nitric Acld Resistance of Coating | After testing in 70nitric acld solution for 30min the color of coating surface shall not change | |
18 | Detergent Resisitance of Coating | After dipping in 38C 3 detergent solution the adhesion of dry film shall not drop there shall have no bubbies and changes |
ceiling & ceiling tile &aluminum ceiling tile